- Vessel in same condition as in question 10, consume the following while on passage :
- All the HFO (200t) from NO1 DB .
- Half the HFO (i.e 100t) from NO3c .
- All the FW from NO4 P and S (total 200t ) .
Find the fluid the GM on the arrival at the next port .
NOTE 4 : Find KG on the arrival by taking moments about keel , as explained in chapter 7 , and add an extra column for the changes in FSM , as shown below . Bear in mind notes 1,2 and 3 , under question 11.
Remarks
Weight (t) KG Moment About FSM
L D M Keel TM TM
In question #2 doesn’t it need to convert into 0.050??
Where is the solution for que 18&19 ?
yes, question number 20, solid gm is 0.9, subtract fsc and get fluid gm and then apply RM=WGMSinx
the breath of the load water plan of a ship 90m long measured at equal intervals from forward are as follow 0,3.96,8.53,11.58,12.19,12.5,11.58,5.18,3.44, and 0.3m respectively.if the load draft is 5m and the block coefficient is 0.6. find the freshwater allowance and position of the centre of floatation
Very helpful to solve questions
Sir . There is some mistake in the solution of 20th question of FSC..
Thanks for the easy calculations..