Maintenances of the immersion suit are:
- Check the physical condition of the immersion suit;
- The zip is smooth and wax it if required;
- Every immersion suit should be tested with constant air pressure of 0.02 bar for a period of atleast 15 mins;
- Check for leaks using a leak detection fluid;
- Check the light is working and not expired;
- The SOLAS tape is in good condition, renew if required;
- The whistle is working;