- What is declared under SOLAS convention?
- CRB
- ORB
- Procedure and arrangement manual
- Bulk carrier booklet
ANS.: D
- Which coastal zone can extend beyond 200nm from baseline?
- Exclusive economic zone
- Continuers’ zone
- Fisher zone
- Continental zone
ANS.: D
- DPA requires under
- STCW code
- ISPS
- MARPOL73/78
- ISM code
ANS.: D
- Minimum no of life buoys of cargo ship of 200m and more.
- 12
- 14
- 18
- 24
ANS.: B
- EEBD service time
- 15
- 10
- 20
- 30
ANS.: A
- Cause liability of ship occurs in case of loss of life.
- CORE 1974
- CLC 1969
- FUND 1971
- LLMC 1976
ANS.: D
- Annex I regulation 12 sludge takes concentration
- Bilge pump to OWS
- No line direct connection to OBD other than discharge give in regulation 13
- No direct connection to OBD
- Have direct connection to OBD all the valve to be close and sealed
ANS.: B
- The presence of toxic gases is measured by
- Explosive meter
- O2analyser
- LEL
- None
ANS.: A
- Immersion suit donning time without assistance
- 30sec
- 1min
- 3min
- 2min
ANS.: D
- Annex I collection of residue tank washing and also oily mixture to be
- Bilge tank
- Sludge tank
- Oily bilge tank
- Slop tank
ANS.: D
- Class D fire
- Fire in metal
- Fire in liquid
- Fire in electrical system
- None
ANS.: A
- Minimum capacity of SCBA
- 1800L
- 1200L
- 1500L
- 600L
ANS.: B
- Parent instrument for the mandatory ISM code
- SOLAS CH-IV
- SOLAS & MARPOL
- SOLAS CH-XI
- UNCLOS
ANS.: C
- A state party to treaty or convention after the convention been recognized and signed by other parties and enters into force this action is called.
- Ratification
- Acceptance
- Approval
- Accusation
ANS.: A
- In special areas any discharge of oil and oil mixtures from machinery spaces
- Prohibited
- Enroute and min 12NM
- Enroute and min 50NM
- Enroute with oil filtering equipment
ANS.: A
- Standard discharge connection flange as per MARPOL ANNEX I Regulation (od-pcd-th)
- 200,185,15
- 215,183,20
- 205,185,50
- 200,183,20
ANS.: B
- Recharging a previously used cartridge-operated dry chemical fire extinguisher is accomplished by ______________.
- authorized fire equipment servicing personnel only
- replacing the propellant cartridge and refilling it with pyrotechnic powder
- puncturing the cartridge seal after installation
- recharging the cartridge and then refilling it with powder
ANS.: B
- A load line for a ship is assigned by ______________.
- Port health inspector
- Assessors and Arbitrators
- Institute of Marine Engineers
- A recognized classification society approved by the Administration.
- Company of Master Mariners.
ANS.: D
- In the event of a galley fire on board a general cargo ship, most dry chemical or carbon dioxide portable extinguishers are automatically activated through the action of a stainless steel cable, spring and a ____________.
- fusible link of tritium, gallium arsenide alloy
- stack switch with sensors
- thermostat of bimetallic type
- pyrostat with activation of pyrotechnics
- none of the above
ANS.: E
- The stability of a vessel is normally the greatest when all fuel and water tanks are full because the _____________.
- center of gravity is lowered
- center of buoyancy is lowered
- reserve buoyancy is unchanged
- hull freeboard is increased
ANS.: A