How team is formed in case of emergency on ships ?

COMMAND TEAM
ROVING TEAM / ENG ROOM SQUAD
SHIP NO.RANKDUTY SHIP NO. RANKDUTY
M-1MASTERBRIDGE-IN COMMAND E-1CH ENGIN CHARGE
D-22ND OFFBRIDGE-COMMUNICATION E-6EL.OFFASST INCHARGE
D-5DK. CDT2BRIDGE-STEERING E-5AEOASSIST AS REQUIRED
D-8S’HMAN 1BRIDGE-STEERING E-8D.Gr. 1ASSIST AS REQUIRED
 E-9D.Gr. 2ASSIST AS REQUIRED
EMERGENCY SQUAD
 
SERVICE SQUAD
SHIP NO.RANKDUTY SHIP NO.RANKDUTY
D-1CH. OFF* IN CHARGE D-33RD OFFINCHARGE
E-22ND ENGASST INCHARGE E-44TH ENGASST INCHARGE
E-33RD ENGASSIST AS REQUIRED D-4DK. CDT1ASSIST AS REQUIRED
D-7DK.SRNGASSIST AS REQUIRED D-6DK. CDT3ASSIST AS REQUIRED
D-9S’HMAN2SCBA D-11SMAN IICLOSE VENTS/DOORS
D-10S’HMAN3SCBA D-12DUHCLOSE VENTS/DOORS
E-7FITTERSCBA S-1CH.CK.STRETCHER / FIRST AID KIT
E-10D.Gr. 3SCBA S-2G.S.STRETCHER / FIRST AID KIT
* In case of Engine Room fire 2nd Eng will be Incharge.      
           
DESIGNATED MUSTER POINT : STBD SIDE GANGWAY DECK  
ALTERNATE MUSTER POINT:  PORT SIDE “A” DECK
A. Substitute of Key Personnel:  Ch. Officer’s substitute will be the 2nd Officer 
The Master’s substitute will be the Ch. Officer.2nd Engineer’s substitute will be the 3rd Engineer 
Ch. Engineer’s substitute will be the 2nd Engineer.3rd Officer’s substitute will be the 4/engr  
B. 3rd/Off, 4th Eng and El/Off are responsible for the maintenance of all LSA and FFA on board the ship,  
    under the guidance of Chief Officer.       
C. All supernumeraries to stand by on bridge when Emergency alarm sounds.    
           
1. Fire alarm shall be sounded immediately on discovery of a fire and then Master informed.   
2. Upon hearing the fire alarm all persons shall muster at emergency muster station carrying their life jackets and their assigned fire fighting equipment.
3. Watchkeepers shall remain on watch until relieved, they shall give clear details of the situation to their reliever before taking up their station as per this muster list.
4. Chief Officer shall be fire fighting supervisor for fire on deck, holds or accommodation. Chief Engineer shall be fire fighting supervisor for fire in E/R, boiler flat or steering flat.
5. Fire fighting supervisor shall instruct emergency squad for fire fighting and support squad for providing back up, other FFA, closing vents, flaps, doors, boundary cooling etc.
6. Support squad shall prepare lifeboats and liferafts for launching when ordered by Master.    
7. On ships having 4 SCBA sets, 2 fire fighting teams may be formed from emergency squad, if required.
8. Fire fighters shall wear protective clothing along with SCBA.
CAUTION:
1. Fixed fire extinguishing system gas shall be released by fire fighting supervisor only when ordered by Master.
2. Prior release of Foam to E/R, Main engine shall be stopped, E/R abandoned and sealed. Abandonment by personnel shall be confirmed with a head count.
3. Prior release of Foam to other compartments, abandonment by personnel shall be confirmed by head count and compartment sealed.
4. Entry to fire zones or fire compartments by fire teams shall be in pairs only
Note: Above mentioned Rank/Duties is only for reference. Master may allot ship specific duties as required. MASTER

AMIT KUMAR

About the author

Vikrant_sharma

Leave a Comment

From Marine Enclyopedia to MARINE GYAAN ACADEMY in Lucknow - Preparing YOUTH to become SEAFARERS ( for IMU-CET and various courses) From Marine Enclyopedia to MARINE GYAAN ACADEMY in Lucknow - Preparing YOUTH to become SEAFARERS ( for IMU-CET and various courses) From Marine Enclyopedia to MARINE GYAAN ACADEMY in Lucknow - Preparing YOUTH to become SEAFARERS ( for IMU-CET and various courses) From Marine Enclyopedia to MARINE GYAAN ACADEMY in Lucknow - Preparing YOUTH to become SEAFARERS ( for IMU-CET and various courses)